In-Room Climate Control
Connected control at your Pelican thermostat or online.
In-Room Climate Control
Connected control at your Pelican thermostat or online.
Commercial Connected
Thermostat
TC Series
Intuitive Control. Anywhere, Anytime.
Optimized Scheduling
Our scheduling system gives you full control over optimal
temperature adjustments while still giving room occupants
limited flexibility within your defined set-point ranges.
Web Connected
The Pelican Connect web-app allows you to make
adjustments in an instant from anywhere.
Intuitive Control. Anywhere, Anytime.
Optimized Scheduling
Our scheduling system gives you full control over optimal temperature adjustments while still giving room occupants limited flexibility within your defined set-point ranges.
Web Connected
The Pelican Connect web-app allows you to make adjustments in an instant from anywhere.
Intuitive Control. Anywhere, Anytime.
Optimized Scheduling
Our scheduling system gives you full control over optimal temperature adjustments while still giving room occupants limited flexibility within your defined set-point ranges.
Web Connected
The Pelican Connect web-app allows you to make adjustments in an instant from anywhere.
Real-Time Data. Instant Visibility.
Real-time data is continuously pushed to the Pelican cloud for historical tracking and fast issue detection. Keeping you updated at all times on site and online.
View key details and active settings, like configuration, humidity,* CO₂ readings**, and active alarms, all on screen.
* Only availible on the TC2 or TC4 thermostats.
** Only availible on the TC3 or TC4 thermostats.
Real-Time Data. Instant Visibility.
Real-time data is continuously pushed to the Pelican cloud for historical tracking and fast issue detection. Keeping you updated at all times on site and online. View key details and active settings, like configuration, humidity,* CO₂ readings**, and active alarms, all on screen.
* Only availible on the TC2 or TC4 thermostats.
** Only availible on the TC3 or TC4 thermostats.
Full Control. Customized Access.
The Pelican Connect web-app gives you full control to lock your thermostat manually or by schedule, so only authorized users can make changes or hide all controls entirely for a descreet display with the minimal option.
If you are looking to give users limited access, you can set it to temperature only to hide the Mode or Fan buttons to still allow occupants access to adjust the temperature within your defined ranges without fully locking the thermostat.
Full Control. Customized Access.
The Pelican Connect web-app gives you full control to lock your thermostat manually or by schedule, so only authorized users can make changes or hide all controls entirely for a descreet display with the minimal option. If you are looking to give users limited access, you can set it to temperature set points only to hide the Mode or Fan buttons to still allow occupants access to adjust the temperature within your defined ranges without fully locking the thermostat.
Intergrated Monitoring. Automatic Optimization.
CO₂ Ventilation Optimization
Available on the TC3 model
When CO₂ levels rise, Pelican sends alerts through the web app and, optionally, displays them on the thermostat. The smart system then increases ventilation automatically and when paired with a Pelican economizer controller, adjusts the outside air damper to bring in fresh air.
Humidity Comfort Optimization
Available on the TC2 model
CO₂ & Humidity Optimization
CO₂ monitoring and humidity monitoring capabilities keep you fully informed at the thermostat or online. The Pelican system keeps the CO₂ and humidity levels optimized. Smart adjustments work behind the scenes to keep your site’s climate healthy, balanced, and comfortable without manual intervention.
Always Adapting for Comfort
No matter the mode, The Pelican ecosystem automatically manages everything behind the scenes: responding to each thermostat’s demand and coordinating valves, fans, stages, and plant systems to deliver consistent, reliable comfort.
When set to Off, the system automatically purges residual heating or cooling load, then safely powers down equipment to avoid waste and capture the full energy-saving benefit.
Always Adapting for Comfort
When set to Off, the system automatically purges residual heating or cooling load, then safely powers down equipment to avoid waste and capture the full energy-saving benefit.
Beyond Simple Fan Control
At the thermostat, users can choose betwee Auto and On for basic fan control.
Behind the scenes, the Pelican system ensures proper ventilation by guaranteeing minimum fan run-time and maintaining the correct fan speeds.
And when connected to a Pelican Economizer
Controller, the system also adjusts the outside air
damper automatically to meet your ventilation needs.
Beyond Simple Fan Control
Behind the scenes, the Pelican system ensures proper ventilation by guaranteeing minimum fan run-time and maintaining the correct fan speeds.
And when connected to a Pelican Economizer Controller, the system also adjusts the outside air damper automatically to meet your ventilation needs.
Intergration Made Effortless
Compatible with conventional, heat pump, multi-zone damper, fan coil, hot water, chilled water systems—and more. Pelican’s innovative 3-wire retrofit module makes replacement simple, turning outdated climate systems into modern, connected controls.
Connected Climate. Expanded Capabilities.
The Pelican solution goes far beyond the intuitive wall-mounted display. Our system’s capabilities extend to a range of controllers designed to handle complex and unique climate control applications seamlessly and intelligently. Our controllers integrate seamlessly with Pelican thermostats and the full Pelican climate control ecosystem, giving you the flexibility to choose the smart features that work best for you and your business based on expert recommendations.
Wired External Sensor: TA1
This multi-faceted device flexibly measures space temperature, supply temperature, or other essential temperature points to support accurate system control and monitoring.
Advanced Functions:
Discharge Air Temerature Sensor
Remote Room Temperature Sensor
Occupancy Sensor Input
Dry-Contact Input Notification
Stand Alone External Temperature Sensor
Advanced Rooftop Controller: PEARL
This device wires directly to a Pelican thermostat to provide intelligent sequencing for advanced equipment and economizer control, ensuring tuned comfort, proper ventilation, and peak energy performance.
Advanced Functions:
Real-Time Demand Ventilation
When paired with a CO₂ Pelican thermostat**, the PEARL continuously monitors occupancy and automatically adjusts ventilation based on real-time demand. It also monitors space, supply, and outside temperatures, and damper position.
**Only available with a TC3 or TC4 connected
Modulating Cooling Management
Modulating Heating Management
Advanced Equipment Failure Warning Notifications
Enhanced Historical Data Tracking
View temperatures (space, supply, return, outside), damper position, HVAC calls, and CO₂ levels** live online. Access up to two years of trend data through interactive graph
**Only available with a TC3 or TC4 connected
PEARL Expansion Module: PEM-VDC
This accessory adds two additional modulating outputs to the PEARL, enabling precise heating and cooling modulation to achieve a target discharge air temperature.
The PEARL Expansion Module is an optional accessory is designed to expand functionality only when required for specific HVAC equipment, keeping costs down for our customers who do not require the additional outputs.
Connected Climate. Expanded Capabilities.
Wired External Sensor: TA1
This multi-faceted device flexibly measures space temperature, supply temperature, or other essential temperature points to support accurate system control and monitoring.
Advanced Functions:
Discharge Air Temerature Sensor
Remote Room Temperature Sensor
Occupancy Sensor Input
Dry-Contact Input Notification
Stand Alone External Temperature Sensor
Advanced Rooftop Controller: PEARL
This device wires directly to a Pelican thermostat to provide intelligent sequencing for advanced equipment and economizer control, ensuring tuned comfort, proper ventilation, and peak energy performance.
Advanced Functions:
Real-Time Demand Ventilation
When paired with a CO₂ Pelican thermostat**, the PEARL continuously monitors occupancy and automatically adjusts ventilation based on real-time demand. It also monitors space, supply, and outside temperatures, and damper position.
**Only available with a TC3 or TC4 connected
Modulating Cooling Management
Modulating Heating Management
Advanced Equipment Failure Warning Notifications
Enhanced Historical Data Tracking
View temperatures (space, supply, return, outside), damper position, HVAC calls, and CO₂ levels** live online. Access up to two years of trend data through interactive graph
**Only available with a TC3 or TC4 connected
PEARL Expansion Module: PEM-VDC
This accessory adds two additional modulating outputs to the PEARL, enabling precise heating and cooling modulation to achieve a target discharge air temperature.
The PEARL Expansion Module is an optional accessory is designed to expand functionality only when required for specific HVAC equipment, keeping costs down for our customers who do not require the additional outputs.
Technical Specifications
| TC1 Thermostat | TC2 Thermostat | TC3 Thermostat | TC4 Thermostat | |
|---|---|---|---|---|
| Part Number: | TC1 | TC2 | TC3 | TC4 |
| Humidity Sensor: | -- |
Humidify setting: 10 - 80% RH Dehumidify setting: 20 - 90 RH |
-- |
Humidify setting: 10 - 80% RH Dehumidify setting: 20 - 90 RH |
| CO2 Sensor | -- | -- |
400 - 2000 PPM detection range. +/- 50 PPM accuracy @ 600 PPM and 1000 PPM, auto-calibrating. |
400 - 2000 PPM detection range. +/- 50 PPM accuracy @ 600 PPM and 1000 PPM, auto-calibrating. |
| Operating Range: |
-4°F to 122°F 5% to 90 % Relative Humidity (non-condensing) |
-4°F to 122°F 5% to 90 % Relative Humidity (non-condensing) |
-4°F to 122°F 5% to 90 % Relative Humidity (non-condensing) |
-4°F to 122°F 5% to 90 % Relative Humidity (non-condensing) |
| Relay Current Rating: | 2.0A running (Y, Y2, W, W2, G) | 1.0A running (Dh & Hu) | 2.0A running (Y, Y2, W, W2, G) | 1.0A running (Dh & Hu) |
| Temperature Deadband: | 3°F setting, auto-adjusting to 5°F | 3°F setting, auto-adjusting to 5°F | 3°F setting, auto-adjusting to 5°F | 3°F setting, auto-adjusting to 5°F |
| Wireless Frequency: | 2.4 GHz Mesh Networking | 2.4 GHz Mesh Networking | 2.4 GHz Mesh Networking | 2.4 GHz Mesh Networking |
| Wireless Standards: | IEEE 802.15.4 | IEEE 802.15.4 | IEEE 802.15.4 | IEEE 802.15.4 |
| Operating Voltage Range: | 23 - 30 VAC | 23 - 30 VAC | 23 - 30 VAC | 23 - 30 VAC |
| Power: | 24 VAC, 60 Hz, 105mA | 24 VAC, 60 Hz, 105mA | 24 VAC, 60 Hz, 105mA | 24 VAC, 60 Hz, 105mA |
| FCC Compliance: | Class B part 15 | Class B part 15 | Class B part 15 | Class B part 15 |
| Dimensions: |
5.2 X 3.9 X 0.75 in (132 X 99 X 19 mm) |
5.2 X 3.9 X 0.75 in (132 X 99 X 19 mm) |
5.2 X 3.9 X 0.75 in (132 X 99 X 19 mm) |
5.2 X 3.9 X 0.75 in (132 X 99 X 19 mm) |
| Mounting: | Vertical Mount | Vertical Mount | Vertical Mount | Vertical Mount |
| Storage: | -20°F –160°F | -20°F –160°F | -20°F –160°F | -20°F –160°F |
| TC1 Thermostat | TC2 Thermostat | TC3 Thermostat | TC4 Thermostat | |
|---|---|---|---|---|
| Part Number: | TC1 | TC2 | TC3 | TC4 |
| Humidity Sensor: | -- |
Humidify setting: 10 - 80% RH Dehumidify setting: 20 - 90 RH |
-- |
Humidify setting: 10 - 80% RH Dehumidify setting: 20 - 90 RH |
| CO₂ Sensor | -- | -- |
400 - 2000 PPM detection range. +/- 50 PPM accuracy @ 600 PPM and 1000 PPM, auto-calibrating. |
400 - 2000 PPM detection range. +/- 50 PPM accuracy @ 600 PPM and 1000 PPM, auto-calibrating. |
| Relay Current Rating: | 2.0A running (Y, Y2, W, W2, G) | 1.0A running (Dh & Hu) | 2.0A running (Y, Y2, W, W2, G) | 1.0A running (Dh & Hu) |
| Operating Range: |
-4°F to 122°F 5% to 90 % Relative Humidity (non-condensing) |
-4°F to 122°F 5% to 90 % Relative Humidity (non-condensing) |
-4°F to 122°F 5% to 90 % Relative Humidity (non-condensing) |
-4°F to 122°F 5% to 90 % Relative Humidity (non-condensing) |
| Temperature Deadband: | 3°F setting, auto-adjusting to 5°F | 3°F setting, auto-adjusting to 5°F | 3°F setting, auto-adjusting to 5°F | 3°F setting, auto-adjusting to 5°F |
| Wireless Frequency: | 2.4 GHz Mesh Networking | 2.4 GHz Mesh Networking | 2.4 GHz Mesh Networking | 2.4 GHz Mesh Networking |
| Wireless Standards: | IEEE 802.15.4 | IEEE 802.15.4 | IEEE 802.15.4 | IEEE 802.15.4 |
| Operating Voltage Range: | 23 - 30 VAC | 23 - 30 VAC | 23 - 30 VAC | 23 - 30 VAC |
| Power: | 24 VAC, 60 Hz, 105mA | 24 VAC, 60 Hz, 105mA | 24 VAC, 60 Hz, 105mA | 24 VAC, 60 Hz, 105mA |
| FCC Compliance: | Class B part 15 | Class B part 15 | Class B part 15 | Class B part 15 |
| Dimensions: |
5.2 X 3.9 X 0.75 in (132 X 99 X 19 mm) |
5.2 X 3.9 X 0.75 in (132 X 99 X 19 mm) |
5.2 X 3.9 X 0.75 in (132 X 99 X 19 mm) |
5.2 X 3.9 X 0.75 in (132 X 99 X 19 mm) |
| Mounting: | Vertical Mount | Vertical Mount | Vertical Mount | Vertical Mount |
| Storage: | -20°F –160°F | -20°F –160°F | -20°F –160°F | -20°F –160°F |
Standard Features
Schedule
- Daily, 5-2, and 7 Day Occupied/Unoccupied Schedule.
- Up to 12 set times per day.
- Optimum Start.
- 365-day vacation calendar.
- Vacation mode button.
- Event calendar.
- Enforced fan circulation.
System Protections
- Tamper proof security screw.
- Four minute short cycle timer.
- Temporary schedule override allowance.
- Schedulable keypad lockout.
- 365-day vacation calendar.
- Limit heat and cool set-point ranges.
- Auto-adjusting 5°F heat and cool dead-band.
Alerts and Notifications
- Analytics based cool and heat failure notification.
- Temperature safe range notification.
- Unable to find wireless network notification.
- Unable to connect to cloud server notification.
- Unreachable device notification.
- Utility event active notification.
Standard Features
Schedule
- Daily, 5-2, and 7 Day Occupied/Unoccupied Schedule.
- Up to 12 set times per day.
- Optimum Start.
- 365-day vacation calendar.
- Vacation mode button.
- Event calendar.
- Enforced fan circulation.
System Protections
- Tamper proof security screw.
- Four minute short cycle timer.
- Temporary schedule override allowance.
- Schedulable keypad lockout.
- 365-day vacation calendar.
- Limit heat and cool set-point ranges.
- Auto-adjusting 5°F heat and cool dead-band.
Alerts and Notifications
- Analytics based cool and heat failure notification.
- Temperature safe range notification.
- Unable to find wireless network notification.
- Unable to connect to cloud server notification.
- Unreachable device notification.
- Utility event active notification.